8 EATON 420 Mobile Piston Pump Technical Manual E-PUPI-TM002-E4 November 2014
Control Options
Pressure Compensator
Pressure Compensator
Control
The pump will provide a con-
tinuously modulated ow to
meet changing load demands
at a pre-adjusted compensa-
tor pressure. At pressures
below the compensator set-
ting, the pump will operate
at maximum displacement.
See model code on page 4
for compensator pressure
ranges.
Warning: The pressure com-
pensator may be adjusted
beyond the rated pressure
of the pump. When adjusting
the pressure limiter, install a
0-350 bar (0-5000 psi) gage
in the outlet gage port and
limit the pressure setting to
the continuous rated pres-
sure for the pump displace-
ment shown on page 6.
Pressure Limit Settings
The pressure compensator
uses two springs to cover
the full pressure range of
the ADU pumps. The high
pressure spring covers the
range from 140 bar (2050 psi)
to 280 bar (4060 psi). The low
pressure spring is adjustable
from minimum pressure
through 140 bar (2050 psi).
Pressure Cut-off
Characteristics of
Pressure Compensa-
tor Control
at 49°C (120°F),
static conditions.
“K” Inlet
Gage Port
“B” Inlet
“F” Case Drain
“C” Outlet
To Load
See Model Code on Page 4 for
Spring (Pressure) Adjustment Ranges.
“K” Outlet
Gage Port
Change in
Pressure A
Outlet Pressure
Outlet Flow
Change
in Flow B
Q
P
+
+
Dynamic Response per SAE J745 (Using Swash Plate Position)
Response Recovery
(off stroke) (on stroke)
msec msec
ADU041 20 75
ADU049 20 75
ADU062 25 90
ADU080 26 75
Outlet Pressure
Outlet Flow
Q
P
Outlet Pressure
Outlet Flow
Q
P
Code C - Page 8Code A & B - Page 7