11 EATON 420 Mobile Piston Pump Technical Manual E-PUPI-TM002-E4 November 2014
Control Options
Remote Pressure Control
Remote Pressure Control
Remote relief valve is to be
connected to pilot port “J”
through necessary external
piping. Standard differential
pressure of 20 bar is set
at RPC spool. The required
outlet pressure (below 280
bar) can be set by adjusting
remote relief valve setting.
Once pressure reaches pre-
set value, ow across remote
relief valve starts, this results
in RPC spool movement due
to pressure imbalance. This
will de-stroke the pump to
maintain the set pressure.
Secondary pressure compen-
sator is provided to limit the
max pressure setting as a fail
safe measure. The delta pres-
sure is factory set which can
not be changed.
Delta Pressure setting at control valve - bar (psi) 14 - 24 (200 - 350)
Control uid consumption - lpm (gpm) 4.5 (1.2) max.
Recommended ow rating of remote relief valve- lpm (gpm) 3 – 5 (0.8 – 1.32)
Recommended Eaton Relief Valve part number RV5-10-S-0-50
* Flow Compensator is not
available with RPC.
* Flow Compensator/
Remote Pressure Control
setting should be selected
within range of 10-24 bar
(140-350 psi).
* Remote relief valve is not
included in supply scope of
the pump.